Can the cut-off valve and the valve be used in combination?

Source: Shanghai Valve Factory Co., Ltd. | Published: 2023-12-29

Describes the difference between the cut-off valve and the valve.

01

Structure

Where space is limited, care should be taken to select:

When the valve core and valve seals are always in contact and friction with each other, the seals are easily worn. When the valves are close, the pipes are subject to a wide range of pressure, which exacerbates the wear of the seals.

The valve will be more complex in structure than the terminal valve. From the surface, in the same diameter, the valve is higher than the terminal valve and the valve is longer than the valve. In addition, the valves are divided into clear and dark poles. There are no cut-off valves.

02

Principles of work

When the valve opens and closes, it is an upward valve type, that is to say, turn the wheel, which rotates and lifts with it. The valve is a turn-off wheel, which moves the valve up and down, and the wheel itself remains the same.

The terminal valves specify the direction to be followed by the import and export, and they do not require the direction to be followed by the import and export.

In addition, the valves have only two states: full- or full-open. The locks open for a long time. The valves are much smaller, and the valves can be stopped somewhere in the movement to regulate the flow. The valves can be cut off without any other function.

03

Discrepancies.

Cut-off valves can be used for cut-off and flow regulation. The cut-off valves have greater fluid resistance and are more laborious when they are released, but because of the shorter distance between the valve plate and the sealed surface, the break-out journey is shorter.

Since the valves can only be fully opened and shut down, the movement resistance of the intermediates of the valve passages is almost zero, so the opening of the valves will be very energy-efficient, but the locks will be kept away from the seal and open for long periods of time.

04

Installation and Flow

The end valves need to be installed strictly in the direction marked by the arrows. The direction of the exit valves is specified, and the “tripleization” of the valves provides for the flow of the valves from the top down.

The cut-off valves are low and high, and there are obvious conduits that are not on a parallel horizontal line from the surface. The flow of the valves is on a horizontal line. The trip of the valves is larger than the cut-off valve.

From the point of view of current resistance, the full-time valves are small and the valves are very high. The normal valves have a flow factor of about 0.08 ~ 0.12, with low opening power, so the medium can move in both directions. The normal cut-off valves are three to five times the valves. The sealing is only possible when closed. The core of the valves is exposed to the seal surface when completely closed.

There are two ways to install the cut-off valve. One is that the medium can enter below the core. The advantage is that when the valve closes, the root is free of pressure and can extend the active life of the root and replace the root when the pipe in front of the valve is under pressure; the disadvantage is that the valve drives a large twist, which is about twice as large as the upper flow.

Thus, this method is generally applied only to small diameter cut-off valves (below DN50), and the DN200 or more cut-off valves select the way in which the medium flows from above. (Electron cut-off valves typically enter from above.) The disadvantages of the medium entering from above are the opposite of those of the lower entry.

05

Seal it.

The seal surface of the valve is the side of the ladder of the core (specifically looking at the shape of the core). Once the core is dropped, it is equivalent to the closure of the valve (if the pressure is large, of course it is not strict, but it has a good reverse effect). The valve is sealed on the side side of the plate of the valve, which is less effective than the cutoff than the cut-off valve.