1 Adjustment to open pressure (integrated pressure)

Within the prescribed working pressure range, the opening pressure can be adjusted by rotating the screws to change the pre-heavy compression of the springs. When the valve caps are removed, the locks are broken and the locks are tightened, the bolts are adjusted. First, the import pressure is raised and the valves jump once. If the pressure is activated, the bolts are tightened in the direction of the clockwise; if the pressure is activated, the direction of the counterclockwise needle is eased. When the pressure is adjusted to the required opening pressure, the locks are tightened and the cap is installed.

If the required opening pressure exceeds the working pressure range of the spring, another suitable spring of the working pressure range will need to be replaced, and the corresponding data on the inscription will then be adjusted when the spring is replaced.

In adjusting the opening pressure, the following should be noted:

When the medium pressure is close to the opening pressure (more than 90% of the opening pressure), do not rotate the screws in order to avoid valve rotation and damage to the seal surface.

In order to ensure the accuracy of opening pressure values, adjust the medium conditions used, such as the type of medium and the temperature of the medium, as close as possible to the actual working conditions. When the type of medium changes, especially from the liquid phase to the gas phase, the opening pressure changes frequently. When the working temperature increases, the opening pressure decreases. Therefore, when the constant temperature adjustment is used for high temperatures, the fixed pressure at the constant temperature should be slightly greater than the opening pressure of the ball.

3 Adjustments to emission and return pressures

When the pressure is rotated to the right counterclockwise, the pressure and the pressure of the loop is reduced; on the contrary, when the wheel is rotated to the left, the pressure and pressure of the loop is reduced, the pressure of the pressure and the pressure of the loop is increased. On each adjustment, it is not appropriate to overwhelm the circle (generally within 5 teeth). On each adjustment, it is necessary to tighten the spiral, so that the wheel is inside the sink between the two teeth of the ring, so that there is no sudden rotation of the circle, but no pressure on the side of the circle is reduced. On the other hand, the action test is conducted. For safety purposes, the pressure of the safety valve (generally below 90% of the opening pressure) should be reduced appropriately.

It is important to note that the pressure on the discharge and re-entry pressure of the safety valves is usually only as high as the flow of the gas sources is sufficient to render the valve indissociable (i.e., the rated emission of the safety valves). The test table used to check the safety valves for opening the pressure is very small, the valves cannot be fully opened, and the re-entry pressure is false. In such a test table colonels are allowed to open the pressure, in order to make the jump visible, the regulation circle is usually adjusted to a relatively high position, but under the actual operating conditions of the valves it is not appropriate to reposition the re-positioning the re-positioning of the re-entry circle.

4 Lead Seals

When all safety valves are adjusted, lead should be sealed to prevent any change in the condition of the adjustment. When the safety valves leave the plant, the temperature air will normally be adjusted to the upper limit (i.e., high pressure) of the work pressure level, except as specifically prescribed.