The safety valve is a safety protection valve and an automatic excretion valve. Its release is permanently closed under external force. It opens automatically when the medium pressure in the device or pipeline rises above the specified safety value. In order to prevent the medium pressure in the pipe or device from exceeding the specified safety value, the valve will again close when the pressure returns to normal, preventing the medium from continuing to flow.
Safety valve classification:
(i) Separatization by the opening of the safety valve valve.
1: Microstart safety valve (microstart process height: ⁇ 0.05d0 (minimal larynx calibre discharge)
2: Full-open safety valves (full-open safety valves open at an altitude of 0.25 d (minimum larynx calibre discharges)
(ii) Classification according to the structure of the safety valve
1: The hammer.
2: Leverage
3: Spring (use of compressed springs to balance the pressure of valves to seal safety valves, commonly used at gas transmission stations)
4: The lead (pulse) design main valves and assistive valves, which are driven by the pulse of the auxiliary valves. This structure is usually used for large diameter, large charge and high pressure systems. It is designed to combine the main valves with the auxiliary valves through the pulse of the auxiliary valves.
(iii) Classification by valve structure
1: Closed safety valves (closed safety valves, i.e. excluded media, are not leaked, and all media are released along export to a specified location, generally for toxic and corrosive media.
2: Non-closed safety valves (mostly for air and steam, non-closed safety valves).
(iv) Classification based on the use of media
1: Vapour safety valve (usually represented by A48Y)
2: Safety valves for air and other gases (usually represented by A42Y type)
3: Liquid safety valves (usually represented by A41H)
(5) Distinction by public pressure
1: Low pressure safety valves: PN valve 1.6 Mpa for public pressure
2: Moderate pressure safety valve: commonly known as PN2.5 - safety valve 6.4Mpa
3: High voltage safety valve: PN100.0 - safety valve 80.0 Mpa
4: Ultra-high pressure safety valve: 100 Mpa
(vi) By applicable temperature
1: Ultra-low temperature safety valve: t-100°C safety valve
2: Low temperature safety valve: -100 °C< - safety valve 40 °C.
3: Temperature safety valve: -40°C
4: Medium temperature safety valve: 120°C
5: High temperature safety valve: t>450°C safety valve
(vii) Division by connectivity
1: Francs connected to safety valves. French forms of safety valve import and pipe connection, with flexible forms of export.
2: The screws that connect the safety valves. The safety valve imports and the pipe links the threads, and the export forms are flexible.
3: Link safety valves to weld. Imports and pipelines to screw safety valves, with flexible forms of export.
(viii) Classification based on the principles of operation.
1: Directly. Directly rely on the force generated by the medium pressure to overcome the safety valve that opens the valve by the mechanical load of the valve.
2: Lead safety valves. The safety valves consist of the main valves and the conductor valves, which are driven or controlled mainly by the medium from which the conductor valves are exported.
3: The safety method for additional loads. The additional force for sealing, which can be reliably released when the valve opens, is maintained until the import pressure reaches the opening pressure.
(ix) Sealed by subclassification.
1: Hard alloy seals the hard alloy. This applies to high-temperature high-pressure conditions, especially high-temperature high-pressure overheat vapour.
2:2Cr13 for 2Cr13r13r seal sub-sealed. Usually used for saturated and overheated vapours on containers or pipes, or for other media with temperatures below 450°C.
3: Valve sealing surface is 2Cr13 and valve sealing surface is rigid alloy. Other high-pressure vapours and high current speed media that can easily flush the sealing surface.
4: Valve seals are alloyed steel and valve seals are polytetrafluoroethylene. For oil or gas media, sealing requirements are strict, but work temperatures are below 150°C.
5 : Sealed with austic stainless steel. The valves of this type of safety valve, the valves of which are austic stainless steel, are suitable for the presence of corrosive components such as acid, alkalis, etc. in the medium.
(x) Is there a back-pressure balance institutional classification?
1: Back pressure balance safety valve. Using the original of the balancing back pressure function, such as a bellow, piston or membrane, the valve opens the safety valve for both sides of the upper and lower sides of the respirator's valve.
2: The normal safety method. The safety valve balances the original without back pressure.
The working principles and structure of the spring safety valves:
Motion: The spring power is greater than the normal pressure (pre-selected pressure) of the medium on the core of the valve, and the core is closed. When the inner medium pressure of the tank exceeds the permitted pressure, the spring is compressed, the valve is removed from the valve, the valve is automatically opened, the medium is discharged from the valve and the pressure is reduced; when the pressure returns to normal, the spring pressure pushs the core to the valve and the valve is automatically closed. The role of the safety valve is to prevent the medium pressure in the pipe or device from exceeding the specified pressure, thereby achieving the purpose of safety protection.
Structure:
Valves, valves, seals, locator rings, valves, gaskets, springs, valves, springs, rollers, bolts, bolts, shields, lead seals.
Spring safety valve classification:
Depending on the height of the safety valve, it can be divided into:
(1) Micro-enlightment safety valve: 1/40-1/20 for valve valve valve opening heights of valve throat.
(2) Full-open safety valves: A finger valve opening is generally not less than one quarter of the valve's throat.
Characteristics of full-open safety valves:
1 It is a spring byte load safety valve, which is opened proportionally within the open altitude and then suddenly opens to full open position. The opening altitude is generally not less than one quarter of the flow diameter;
2 A full-open safety valve has a large charge and applies to ultra-pressure protections for pipeline systems such as oil, chemical, power plants, such as gas, liquid, steam, etc.
Characteristics of micro-enlightment safety valves:
It is a direct safety valve, used only for liquid media, with a discharge smaller than a full-opener safety valve.
Spring valve term:
Publicly called pressure: Valves such as PN16 are allowed maximum pressure, PN25, PN40, PN64.
In our country, when it comes to a public pressure, for the sake of clarity, the unit of measure is usually given in the form of “MPA”.
Common diameter: refers to the size of all pipe attachments in the pipeline system expressed in numerical terms to distinguish between those parts that are expressed in screw or outer diameter.
The common diameter is a complete number for reference, which is not identical to the processing size. The common diameter is marked with the letter "DN" and then follows a digital sign. For example, the common diameter of 250 mm should be marked with DN250.
Work pressure: Work pressure means normal pressure that the safety valve itself can withstand.
Pressure level: the pressure range of the spring.
For example, the pressure level is 0.7-1.0 MPa, i.e. the safety valve can open between 0.7 and 1.0. The pressure level set within Mpa is not much related to emission pressure, rated pressure, etc.
Fixed pressure: is the intended pressure of the safety valve valve when it is activated under operating conditions, measured at the surface pressure at the entrance to the valve. That is, when the starting pressure of the safety valve reaches or exceeds this pressure, the safety valve is opened, which is an artificially defined value, usually 1.05-1.1 for the maximum working pressure. MPa, which is a safety value that is greater than normal working pressure of the equipment and less than the design pressure of the equipment.
The calibration pressure of the safety valve is the calibration pressure of the safety valve when it leaves the factory. For spring safety valves, the calibration pressure can be adjusted to the contraction of the spring according to the condition of the protected equipment.
Emission pressure: The upper limit of the emission pressure shall be required by national standards or norms.
Return pressure: After the release of the safety valve, the valve re-presses the valve, and the import pressure when the medium stops discharge. The return pressure is an important parameter for the quality of the use of the safety valve.
Open pressure (gap pressure): The import pressure of the safety valve valve when it begins to rise under operational conditions, under which there is a measurable opening altitude, the medium is in a state of continuous discharge and can be carried out by visual or hearing support.
Flow area: is the minimum cross-section area between the port end of the valve and the closed seal, which is used to calculate the theoretical charge without any resistance.
Channel diameter: refers to the diameter applied to the area of the channel.
Open height: the finger valve exits the actual elevation from the closing position.
Theoretical charge: refers to the calculated charge for the ideal nozzle, and the area of the flowway is equal to the area of the safety valve.
Flow coefficient: refers to the ratio of actual to theoretical discharges.
Sealed test pressure: an imported sealed test pressure at which the leakage rate is measured by closing the seal surface.