What's the difference between the cut-off valve and the throttle?
The valve moves in the form of an lifting pole (up or down of the pole, not of the hand wheel) and a lift or drop rotation pole (up or down of the wheel with the valve, where the nut is on the valve). The cut-off valve is only for full-open and full-off, and regulation and throttle are not permitted.
When the valve is closed, pressure must be exerted on the valve in order to prevent a forced leak. When the medium enters the valve 6 from below the valve, the operational resistance is the force of friction and medium pressure between the valve and the filling. Closing the valve is more powerful than opening the valve, so the diameter of the valve should be large, otherwise the top bend of the valve will fail. In recent years, when the valve appears, the end medium moves from above the valve to entering the valve cavity.
When the valve is opened, the flow reaches its maximum of 25-30% of the nominal diameter, indicating that the valve is fully open. Therefore, the full opening position of the valve should be determined by the valve’s itinerary.
Classification of cut-off valves
The following are common cut-off valves:
1) Direct cut-off valve
2) Straight-flow cut-off valves: In direct or Y-shaped cut-off valves, the flow path of the valves forms an oblique line with the main stream, thus causing less damage to the flow than the traditional cut-off valves, and therefore the loss of pressure through the valves is reduced accordingly.
3) Angular cut-off valves: In an angular cut-off valve, the fluid will only need to change direction once, so that the pressure down through the valve is smaller than the cut-off valves of the traditional structure.
4) Pump-cut-off valves: This form of cut-off valves is a deformation of the traditional cut-off valves. In valves, valves and valves are usually designed according to the principles of the plume. The valves are polished into poles and connected to valves. Seals are made by two flexible seals installed on the plume. The two flex-seaps are separated from one ring, and the seals around the plume are applied to the load pressure pressure on the plume of the valves. The flex-containable seals can be replaced, and they can be made from various materials. The valves are used mainly for “opening” or “closed”, but they can also be used to regulate traffic, with special forms of plumes or special rings.
The cut-off valve has the following advantages:
1. The structure is simple and easy to manufacture and maintain.
2. Work schedule is small and closed for a short period.
3. Good sealing performance, low friction between sealed surfaces and long useful life.
The disadvantages of the cut-off valves are as follows:
1. Fluid resistance is high and greater effort is required when opening and closing.
2. Non-applicable to mediums with particulates, high viscosity and easy to focus.
3. Poor reconciliation performance.
The types of cut-off valves are divided into external threads and inner threads according to the position of the screw of the valve. There is a straight-through, straight-flow and angular pattern depending on the direction of the medium. The cut-off valves are divided into filling-sealed and bellow-sealed ending valves.
Structure of the cut-off valve:
The structure of the cut-off valve consists of a straight-through, straight-flow and straight-angle structure. Straight-through is the most common structure, but it has the greatest fluid resistance. The right-flow resistance is small and is used primarily for fluids containing solid particles or high viscosity. The right-angle valves are mainly made of exercise and are suitable for cut-off valves with small quantities and high pressure.
The following should be noted when installing and maintaining the cut-off valve:
1. Handwheels, handles and end valves may be installed at any location of the pipe.
2. Wheels, handles and conveyances are not allowed to be used for hanging.
3. The medium shall flow in the direction of the arrow indicated by the valve.
The throttle valves control the flow of fluids by altering the cut-off or length of the throttle. If the throttles are combined with the one-way valves, they can be combined into one-way throttle valves. The throttle valves and the one-way throttle valves are simple flow control valves. In a quantitative pump hydraulic system, the throttle valves and spill valves can form three throttle velocity control systems, namely, the flow-rate control system, the flow-rate control system for the flow of oil, the flow-rate control system for the return of the gas. The throttles do not have negative flow feedback function, and cannot compensate for the speed instability caused by changes in loads.
The performance requirements of the throttle are as follows:
• Large-scale traffic regulation and smooth fluctuations in the volume margin;
• Low levels of internal leakage and, if there are external leaks, low levels of external leakage;
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Throttle valves, whose shape and structure are not different from those of the cut-off valves, have different shapes of the closed components. Most of the shut-off components of the throttle are conical line types, which regulate flows and pressures by altering the area of the channel. The throttles are used to reduce media pressure when the pressure is significantly reduced.
This medium moves quickly between the throttle valves and valves, leading to rapid damage to the surface of these parts, known as caricose. In order to minimize the impact of caricidal erosion, the valves are made of caricidal materials (alloy steel) with a peak of 140 ~ 180, which also allows the valves to have a large opening height, which is generally not recommended to flow below a small crack.
The throttle has the following characteristics:
1. Simple structure, easy to manufacture and maintain, and low cost.
2. Reconciliations are not sufficiently precise to be used for reconciliations.
3. Sealed surfaces are perishable and cannot be used to cut off the medium.
4. Sealed performance is poor.
The throttles can be divided into straight-through valves and angular valves by route; depending on the shape of the release package, there are three types: needle shapes, ditch shapes, and window shapes. The throttles should be installed and maintained with the following:
This valve is often required to operate, so it should be installed in an easy-to-operate position.
During installation, care should be taken that the medium is directed in the same direction as the arrow marked on the valve.
The reason for the congestion is:
1. Contaminations such as mechanical impurities or glues in oil, asphalt, and carbon sludge accumulate in the current cracks as a result of oxidation.
As a result of the age of oil or the generation of electrode molecules after squeeze, the metallic surface of the throttle has an electrical grade difference, and the polar molecule is drawn to the gap surface to form a solid boundary sorbent layer. The sorbent thickness is typically 5-8 micrometres, affecting the size of the sorbent gap. When these aggregates and adsorbents increase to a certain thickness, they are washed away by liquid flow and then attached again to the valve. This way, the flow of pulses are formed over and over again.
3. When the pressure of the valve is higher, the pressure of the fluid increases, and the metal surface is more susceptible to friction, resulting in a bit differential. Thus, when the pressure is greater, it is easy to block.
Measures to reduce traffic congestion:
1. Select a thin-edged artery with a large hydrometric radius.
2. Precise filtering and regular replacement of oil.
3. The pressure differential before and after the throttle shall be reduced as appropriate.
4. Use of metal materials with small power levels and use of oil that is stable and resistant to oxidation to reduce roughness on the surface of the throttle.
Application of the throttle
Since the flow of the throttle depends not only on the size of the throttle, but also on the pressure differentials around the throttle. The valve is small and is only available when the load of the performing component is small and the speed stability requirements are low.
For speed-reducing systems with large load changes and high velocity stability of the performance component, pressure compensation for the throttle must be provided to maintain the pressure differentials around and behind the throttle in order to stabilize the flow