1. Open pressure regulation
Before leaving the plant, the safety valve shall adjust the opening pressure to the full value required by the user on a stage-by-stage basis.
In order to ensure that the pressure level of the safety valve is consistent, the user must re-establish the safety valve on site before or before installation to ensure that the pressure level of the safety valve is consistent.
The spring compression is changed by the rotation of the screws and the opening pressure can be adjusted within the working pressure level of the spring indicated by the inscription.
The pressure of the valve import should be reduced to 90% of the opening pressure before the spiral is adjusted. % below to prevent the valve from being rotated when the spiral is adjusted, thereby damaging the seal surface.
In order to ensure the accuracy of the pressure values, adjust the medium conditions of the process, such as the type and temperature of the medium, as close as possible to the actual operating conditions.
When working temperature rises, the pressure is usually reduced. Therefore, the fixed pressure value at constant temperature should be slightly higher than the required open pressure value when adjusted for high temperature. To what extent the height is related to valve structure and material selection, it should be based on the manufacturer’s description.
6 General safety valves are used to fix additional back pressure. When, after inspection, the opening pressure is adjusted (at this time the back pressure is atmospheric), the total value shall be the required open pressure value minus the additional back pressure value.
2. Regulate emission pressure and backseat pressure.
In order to regulate the pressure of discharge and re-entry of the valve, the valve must be tested for movement up to full-open height. Therefore, the adjustment method varies depending on the valve structure only if a large-capacity test or safety valve is installed on the protective equipment.
When the ring rotates to the left, its position rises, the pressure of discharges and the pressure of return decreases. On the contrary, when the circle rotates to the right, its position is reduced, the pressure of discharges and the pressure of return increases. On each adjustment, adjustments are made: the circle cannot be too large (usually several teeth can be rotated). On each adjustment, the diameter of the circle is rotated to the left after adjustment.
When the valves rise, the pressure accumulates, thereby reducing the proportion of the valves to open, and then they are rapidly and quickly opened. Thus, the rise of the valves is likely to reduce the pressure on emissions. It is important to note that the valves cannot rise too close to the valves. However, the level of leakage in the sealed surface can be maintained by opening them.
The upper circle is used to change the rotational angle of the reflection of the lower flow medium of the valve, thereby changing the size of the flower's strength, and thus to adjust the echo pressure. When the upper circle rises, the turner is lower and the flower's strength is lower, thereby increasing the echo pressure. On the contrary, when the upper circle is lower, the echo pressure is lower. Of course, the upper circle not only alters the echo pressure, but also affects the emission pressure, which is higher, and lowers the pressure of discharge, but the effect is less obvious than the return pressure.
3. Lead seals
When the valve is adjusted, the lead seal is applied to prevent any change in the condition of the adjustment.