The safety valve is a special branch of the valve family. Its specificity is that the safety valve, unlike other valves, only acts as a switch and, more importantly, protects the safety of the equipment.
When the medium pressure in the device or pipe exceeds the specified value, the special valve that prevents the medium pressure in the pipe or device from exceeding the specified value by releasing the medium outside the system.
The safety valve is an automatic valve, which is used mainly in boilers, pressure containers and piping, and is controlled at a controlled pressure that does not exceed a specified value and is important for the safety of the person and the operation of the equipment.
With the rapid growth of economic construction in our country, there is an increasing number of pressure-control equipment projects. In view of the need for equipment to depress, safety valves play a crucial role in the protection of equipment.
The safety valves are used mainly for steam boilers, liquefied petroleum gas car tanks or liquefied petroleum gas railway tanks, oil extraction wells, high pressure side roads for steam generation equipment, pressure pipes, pressure containers, etc.
Category of safety valve
The safety valve is generally small and is commonly used between DN15mm-DN80mm, with more than 150mm commonly referred to as the large calibre safety valve.
The safety valves are divided into full-start safety valves and microstart safety valves. Depending on the overall structure and loading of the safety valves, they can be divided into static heavy, leverage, spring and pilot types.
When the working temperature is high and the pressure is not high, it is preferable to choose a lever; springs should be used for high pressure equipment; spring safety valves are generally used.
Installation Method
As part of the debugging of the entire equipment system, the valve is frequently damaged when the valve is opened for the first time because there is always dirt and shredding in the system. To ensure that external impurities do not enter the valve, the entire system should be adequately cleaned prior to installation, and the valve should be installed in a place where the stain, rust, and shredding do not gather.
In steam applications, it is also important to reduce leakage trends through the installation of safety valves. Safety valves should be installed to prevent condensed water from condensing upstream of the valves. As shown in the figure below, safety valves can be installed above the steam pipe.
When the safety valve is properly installed above the steam pipe, the import pipe of the safety valve can function as a self-drainer.
Temperature safety valves should be installed on the top or side of the water heater, as shown in the figure below:
The correct flow of fluids in the safety valves is shown in the figure below.
Attention in installation
(1) The newly installed safety valve shall be accompanied by a product certificate and shall be re-calibrated, lead sealed and the safety valve certified prior to installation.
(2) The safety valve shall be installed vertically and on the container or pipe gas interface.
(3) The export of the safety valves is unobstructed and backpression is avoided, such as the installation of excretion tubes, which shall have a diameter greater than that of the export of the safety valves, which shall be sensitive to freezing, packagings are flammable, toxic, highly toxic, and the excretion tube shall be handled directly to a safe place or facility outside the room, and no valves shall be installed in the excretion tube.
(4) For containers that are flammable, explosive, toxic or viscous media, the end valve may be installed and its structure and diameter size shall not impede the proper operation of the safety valve. In normal operation, the end valve shall be fully open and sealed with lead.
(5) For pressure packagings that are flammable, explosive or toxic, the safety valves must have a safety device and a recovery system. A lever safety valve must be installed vertically with lead and a spring safety valve should be installed vertically so as not to affect its movements. Attention should also be paid to co-ordination, the co-axis of the parts and the balance of the bolts. The safety valves should not be smaller than the circulation section of the safety valve that connects the short tube to the boiler pressure vessel.
Installation experience set
(1) When two phase materials of gaseous liquid are present in the packaging, the safety valve shall be installed in the gas phase.
(2) When a safety valve is used to emit flammable liquid, the export of the safety valve shall be connected to the accident storage tank.
(3) The general safety valve shall be emptied from the ground at a distance not exceeding 15 m (m) by the operator and not exceeding 15 m (m) by the internal fireplace, spark site and high temperature equipment.
(4) When the entrance to a safety valve has a barrier valve, the barrier valve shall be open and shall be sealed with lead in order to avoid error.
(5) The perforation area of the pipe and the pipe between the safety valve and the boiler or pressure vessel shall not be less than the import area of the safety valve; if multiple safety valves share an import pipeline, the circulation area of the import pipe shall not be less than the sum of the import area of the safety valve.
(6) Cut-off valves shall not normally be installed between the safety valves and the boiler's vapour packaging and trunks, nor shall they be induced out of the tube by steam. The cut-off valves or other pull-out tubes shall generally not be installed between the safety valves and pressure containers. For pressure containers that are extremely toxic, highly, moderately hazardous, flammable, corrosive, viscous, or precious media, the safety valves shall be installed between the safety valves and pressure containers only with the approval of the technical head of the user-in-charge pressure vessel. During the normal operation of the pressure vessel, the valves shall be fully opened and shall be sealed or locked with lead.
(7) A spring safety valve connected with a screw shall be connected to a bolted trachea, which shall be welded to the container.
(8) The safety valves shall be equipped with discharge tubes. The discharge valves shall, as far as possible, avoid bending and rushing in order to minimize resistance. The discharge tubes shall flow directly to the safety site and have sufficient circulation interdiction area to ensure a smooth flow of vents. For the safety valves that interact to produce chemical reactions, they shall not be shared; when installed on corrosive, combustible gas equipment, they shall be protected against corruption or fire explosion; the safety valve equipment shall be a toxic medium and the medium vapour density is greater than the air density, and the media and vapour discharged from the safety valves shall be subject to a closed system for recovery from the closed system to production.
(9) The discharge tube of the safety valve shall be fixed so as not to cause excessive additional stress or vibration from the safety valve.
(10) Safety valves installed in the open air shall be equipped with reliable measures to prevent water ice in the inner medium of the valve at temperatures below 0oC, affecting the discharge of the safety valves.
(11) When the temperature of the safety valve is higher than the minimum ambient temperature, the safety valve shall be equipped with an insulation trap and shall be equipped with an insulation to clean the steam, to prevent the medium from blocking the safety valve and to affect the normal functioning of the safety valve. The import and export pipe of the safety valve shall also be designed as a vapour insulation trap or an insulation steam pipe to prevent the media from clinking the pipe.
(12) The safety valve shall be equipped with a device to prevent the automatic movement of the hammer and with a guidance frame to limit the impact of the lever, and the spring safety valve shall be equipped with a device to lift the handle and to prevent any arbitrary tightening of the bolts.
The exit tubes and valves with steam shall not be installed between the safety valve and the boiler or container.
(14) For boilers with a rated vapour pressure of less than or equal to 3.82 MPa, the safety valve shall have a throat diameter of less than 25 mm; for boilers with a rated vapour pressure of more than 3.82ma, the safety valve shall have a throat of less than 20 mm.
(15) The safety valve of the pressure vessel shall be installed directly at the highest position of the pressure container itself. The safety valve of the liquid gas storage tank shall be installed in the gas phase. Short tubes shall generally be connected to the packaging, and the safety valve short tube shall be not less than the safety valve diameter.
(16) The rated evaporation is greater than 0.5 t boiler with at least two safety valves per hour; the rated evaporation is less than or equal to 0.5 t/h boiler with at least one safety valve.
(17) The export of safety valves is unobstructed and backpression is avoided, such as the installation of excretion tubes, which shall have a diameter greater than that of the export of the safety valves, which shall be sensitive to freezing, containers are flammable, toxic, highly toxic, and the excretion tube shall be handled directly to a safe place or facility outside the room, and no valves shall be installed in the excretion tube.