Valve pressure tests are an important procedure before the valve leaves the plant. Pressure tests are the most important and direct method of testing the quality of the valve.
1. Pressure test methods for the end valves: The end valve tests usually place assembled valves in the pressure test frame, open valves, inject media into specified values, check whether the valves and caps are sweating and leaking. The end valve tests can also be conducted separately. Sealed tests are only used as end valves. During the testing process, the end valves are vertically open, the valves open, the medium is introduced from the lower end of the valve, the fillings and gaskets are checked, the valves are closed after qualification, opening the other end, and the leak is checked. If the valve strength and sealability tests are required, the intensity tests can be performed first, then the pressure can be reduced to the required level of the sealing test and the valve can be checked for closure.
The test pressure of the ball valves is: 1 - The valve is half-opened, one end is introduced to the test medium and the other is closed; the ball is rotated several times. When the valves are closed, the closed end is opened for inspection. At the same time, the sealing of the fillings and the gaskets is checked to avoid leakage. The test medium is then introduced from the other end and repeated. 2 - The fixed ball valve sealing test: the ball is rotated several times in front of the test, fixed valves are closed, attracting the test medium from one end to the specified values; the pressure table is used to check the sealing properties of the introduction end, the accuracy of the pressure table is 0.5 to 1 and the scale is 6 times the scale of the 1st level test pressure. No pressure reduction is valid for the specified period; then the test medium is introduced from the other end, and the above-mentioned test is repeated. The valve is then half-opened, two-ends, the inner cavity is full of the medium. Under the test pressure, the pressure sheet and the table is checked and is not leaked at any location.
3. Pressure test methods for valves: the test state of valves: the valve axis is vertically vertically to the level; the valve axis and valve axis are almost parallel to the horizontal line. During the intensity test, the test medium is introduced from the import end to the specified value and the other end is closed. The valve and valve cover are not leaked. The sealed test introduces the test medium from the export end.