Cut-off valves, valves, butterfly valves, stop-valves and ball valves are essential control components of various pipeline systems. Each valve is different in its appearance, structure and even in its functional use. However, the cut-off function of the cut-off valves and valves has some similarities in their shapes. As a result, many friends who have little contact with the valves are confused between the two. In fact, if you look closely, the difference between the cut-off valves and the cut-off valves is still very large.

Structure 01

When the valves are closed and closed, they always interact and friction with each other, and therefore the seals are easily worn. When the valves are close to closure, the pressure on the pipes is very different, which makes the seals worse.

The valve will be more complex in structure than the terminal valve. From the surface, in the same diameter, the valve is higher than the valve and the valve is longer than the valve. In addition, the valve can be divided into clear and dark poles. There are no cut-off valves.

The gate structure, VS cut-off valve.

02 Working principles

When the valve opens and closes, it is an upward valve, that is to say, the wheel rotates and lifts with it. The wheel rotates the valve, which lifts it up and down, and the wheel itself remains in the same position. The flow is different. The valve needs to be fully open or closed, but no cut-off valves are required. The cut-off valves specify the direction of the import/export; the valve does not require the direction of the import/export.

In addition, the valves have only two states: they are fully open or closed. The gates are opened and shut down for a large period of time, opening and closing. The valves are much smaller, and the valves can be stopped somewhere during their exercise. The valves can only be cut off and have no other function.

03 Discrepancies

The cut-off valves can be used both for the cut-off valves and for traffic regulation. The cut-off valves have a relatively high fluid resistance and are labour-intensive when they are released.

Since the valves can only be fully opened and closed, when they are fully opened, the movement resistance of the valve channel intermediates is almost zero, so the opening and closing of the valves will be very energy-efficient, but they are far away from the sealed surface and open and shut for longer periods.

04 Installation and flow

The end valves should be installed strictly in the direction marked by the valve arrow. The direction of the exit valves is also specified. The “three modernizations” of the Chinese valves stipulate that the end valves should flow from the top to the bottom.

The cut-off valves are low and high, and there are apparently pipes that are not on a horizontal line. The valves move on a horizontal line. The valves are larger than the cut-off valves.

From the point of view of mobility resistance, when the valves are fully open, they have a small resistance and a high resistance to the movement of the valves. The mobility resistance of the ordinary valves is about 0.08 ~ 0.12, with a small opening and closure, and the medium can move in two directions. The mobility resistance of the normal cut-off valves is three to five times that of the valves (official account number: pump housekeeper). Seal can only be achieved by forced closure. The valve core of the cut-off valves is exposed to the seal surface when it is completely closed, so the wear of the seals is minimal.

There are two ways to install the end valves. One is that the medium can enter below the core. The advantage is that when the valve is closed, the root is free of pressure and can extend the active life of the root and replace the root while the pipe is under pressure in front of the valve; the disadvantage is that the drive of the valve is larger and approximately twice the upper flow. The valves are subject to a greater axle-direction force, and the valves are easy to bend. Thus, the method is generally only applicable to small diameter end valves (below DN50), and the end valves above DN200 use an inflow of the medium from the top. (Electronal cut-off valves typically use medium access from the top.) The medium enters from the top.